Imaging modalities in the planning of transcatheter aortic valve implantation (standardization of scanning, measurements and reporting protocols)
- Authors: Bulanova M.V.1, Kokov L.S.1,2, Muslimov R.S.1
-
Affiliations:
- N.V. Sklifosovsky Research Institute of Emergency Medicine
- I.M. Sechenov First Moscow State Medical University (Sechenov University)
- Issue: Vol 49, No 1 (2021)
- Pages: 80-88
- Section: REVIEW ARTICLE
- URL: https://almclinmed.ru/jour/article/view/1417
- DOI: https://doi.org/10.18786/2072-0505-2021-49-005
- ID: 1417
Cite item
Full Text
Abstract
This review describes the state of the art on the role of various imaging modalities in pre-operative preparation to transcatheter implantation of biological aortic valve prosthesis, based on the literature data published from 2012 to 2020. One of the key source documents is the consensus of the European Society of Cardiovascular Radiology (ESCR) from 2019, providing the standardized protocols for scanning, measurements and description of the abnormalities identified. The final decision on the procedure of transcatheter aortic valve implantation should be based on the combination of all available diagnostic methods, clinical data and results of imaging by different modalities. Given the most comprehensive information content, the main diagnostic method is computed tomography. The radiologist and the multidisciplinary team should form a single entity, combining clinical and technical knowledge, discussing all the images and conclusions with other team members.
About the authors
M. V. Bulanova
N.V. Sklifosovsky Research Institute of Emergency Medicine
Author for correspondence.
Email: marellabmv@mail.ru
ORCID iD: 0000-0003-4323-6702
Marina V. Bulanova – MD, Radiologist, Department of Radiology
3 Bol'shaya Sukharevskaya ploshchad', Moscow, 129090
РоссияL. S. Kokov
N.V. Sklifosovsky Research Institute of Emergency Medicine;I.M. Sechenov First Moscow State Medical University (Sechenov University)
Email: fake@neicon.ru
ORCID iD: 0000-0002-3167-3692
Leonid S. Kokov – MD, PhD, Professor, Member of Russ. Acad. Sci., Нead of Department of Radiology N.V. Sklifosovsky Research Institute of Emergency Medicine; Head of Chair of Radiology, Institute of Professional Education I.M. Sechenov First Moscow State Medical University (Sechenov University)
3 Bol'shaya Sukharevskaya ploshchad', Moscow, 129090;
8/2 Trubetskaya ul., Moscow, 119991
R. Sh. Muslimov
N.V. Sklifosovsky Research Institute of Emergency Medicine
Email: fake@neicon.ru
ORCID iD: 0000-0002-5430-8524
Rustam Sh. Muslimov – MD, PhD, Leading Research Fellow, Department of Radiology
3 Bol'shaya Sukharevskaya ploshchad', Moscow, 129090
РоссияReferences
- Молчанов АН, Идов ЭМ, Кондрашов АВ, Чернышев СД, Кардапольцев ЛВ, Липская НА. Исторические и современные клинические аспекты транскатетерной имплантации аортального клапана. Вестник Уральской медицинской академической науки. 2016;2(57): 134–146. doi: 10.22138/2500-0918-2016-14-2-134-146.
- Имаев ТЭ, Комлев АЕ, Акчурин РС. Транскатетерная имплантация аортального клапана. Состояние проблемы, перспективы в России. Рациональная фармакотерапия в кардиологии. 2015;11(1):53–59. [Imaev TE, Komlev AE, Akchurin RS. doi: 10.20996/1819-6446-2015-11-1-53-59.
- Cribier A, Eltchaninoff H, Bash A, Borenstein N, Tron C, Bauer F, Derumeaux G, Anselme F, Laborde F, Leon MB. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation. 2002;106(24):3006– 3008. doi: 10.1161/01.cir.0000047200.36165.b8.
- Рабочая группа по ведению пациентов с клапанной болезнью сердца Европейского общества кардиологов (ЕОК, ESC) и Европейской ассоциации кардио-торакальной хирургии (EACTS). Рекомендации ESC/ EACTS 2017 по лечению клапанной болезни сердца. Российский кардиологический журнал. 2018;(7):103–155. doi: 10.15829/1560-4071-2018-7-103-155.
- Martin AK, Mohananey D, Ranka S, Riha H, Núñez-Gil IJ, Ramakrishna H. The 2017 European Society of Cardiology (ESC)/European Association of Cardiothoracic Surgeons (EACTS) Guidelines for Management of Valvular Heart Disease-Highlights and Perioperative Implications. J Cardiothorac Vasc Anesth. 2018;32(6): 2810–2816. doi: 10.1053/j.jvca.2018.05.015.
- Kofler M, Reinstadler SJ, Stastny L, Dumfarth J, Reindl M, Wachter K, Rustenbach CJ, Müller S, Feuchtner G, Friedrich G, Metzler B, Grimm M, Bonaros N, Baumbach H. EuroSCORE II and the STS score are more accurate in transapical than in transfemoral transcatheter aortic valve implantation. Interact Cardiovasc Thorac Surg. 2018;26(3):413–419. doi: 10.1093/icvts/ivx343.
- Терновой СК, Никонова МЭ, Веселова ТН, Имаев ТЭ, Комлев АЕ, Акчурин РС, Федотенков ИС, Шария МА. Мультиспиральная компьютерная томография в планировании транскатетерного протезирования аортального клапана. Российский электронный журнал лучевой диагностики. 2013;3(1):43– 49.
- Базылев ВВ, Воеводин АБ, Шалыгина АС. Среднесрочные результаты транскатетерной имплантации протеза аортального клапана «МедЛаб-КТ». Российский кардиологический журнал. 2019;(8):65–69. doi: 10.15829/1560-4071-2019-8-65-69.
- Воеводин АБ, Алленов АА, Базылев ВВ. Транскатетерная имплантация протеза «МедЛаб-КТ» по методике «клапан-в-клапан». Ангиология и сосудистая хирургия. 2020;26(1): 135–137. doi: 10.33529/ANGIO2020114.
- Blanke P, Weir-McCall JR, Achenbach S, Delgado V, Hausleiter J, Jilaihawi H, Marwan M, Norgaard BL, Piazza N, Schoenhagen P, Leipsic JA. Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR): An expert consensus document of the Society of Cardiovascular Computed Tomography. J Cardiovasc Comput Tomogr. 2019;13(1): 1–20. doi: 10.1016/j.jcct.2018.11.008.
- Chourdakis E, Koniari I, Kounis NG, Velissaris D, Koutsogiannis N, Tsigkas G, Hauptmann KE, Sontag B, Hahalis G. The role of echocardiography and CT angiography in transcatheter aortic valve implantation patients. J Geriatr Cardiol. 2018;15(1):86–94. doi: 10.11909/j.issn.1671-5411.2018.01.006.
- Kenny C, Monaghan M. How to assess aortic annular size before transcatheter aortic valve implantation (TAVI): the role of echocardiography compared with other imaging modalities. Heart. 2015;101(9):727–736. doi: 10.1136/heartjnl-2013-304689.
- Willson AB, Webb JG, Freeman M, Wood DA, Gurvitch R, Thompson CR, Moss RR, Toggweiler S, Binder RK, Munt B, Cheung A, Hague C, Ye J, Leipsic JA. Computed tomography-based sizing recommendations for transcatheter aortic valve replacement with balloon-expandable valves: Comparison with transesophageal echocardiography and rationale for implementation in a prospective trial. J Cardiovasc Comput Tomogr. 2012;6(6):406–414. doi: 10.1016/j.jcct.2012.10.002.
- Agatston AS, Janowitz WR, Hildner FJ, Zusmer NR, Viamonte M Jr, Detrano R. Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol. 1990;15(4):827–832. doi: 10.1016/0735-1097(90)90282-t.
- Takaoka H, Kitahara H, Ota J, Suzuki-Eguchi N, Sasaki H, Mori N, Takahashi M, Iida Y, Matsuura K, Nakayama T, Matsumiya G, Kobayashi Y. Utility of computed tomography in cases of aortic valve stenosis before and after transcatheter aortic valve implantation. Cardiovasc Interv Ther. 2020;35(1):72–84. doi: 10.1007/s12928-019-00618-5.
- Hansson NC, Nørgaard BL, Barbanti M, Nielsen NE, Yang TH, Tamburino C, Dvir D, Jilaihawi H, Blanke P, Makkar RR, Latib A, Colombo A, Tarantini G, Raju R, Wood D, Andersen HR, Ribeiro HB, Kapadia S, Min J, Feuchtner G, Gurvitch R, Alqoofi F, Pelletier M, Ussia GP, Napodano M, Sandoli de Brito F Jr, Kodali S, Pache G, Canovas SJ, Berger A, Murphy D, Svensson LG, Rodés-Cabau J, Leon MB, Webb JG, Leipsic J. The impact of calcium volume and distribution in aortic root injury related to balloon-expandable transcatheter aortic valve replacement. J Cardiovasc Comput Tomogr. 2015;9(5):382–392. doi: 10.1016/j.jcct.2015.04.002.
- Ribeiro HB, Webb JG, Makkar RR, Cohen MG, Kapadia SR, Kodali S, Tamburino C, Barbanti M, Chakravarty T, Jilaihawi H, Paradis JM, de Brito FS Jr, Cánovas SJ, Cheema AN, de Jaegere PP, del Valle R, Chiam PT, Moreno R, Pradas G, Ruel M, Salgado-Fernández J, Sarmento-Leite R, Toeg HD, Velianou JL, Zajarias A, Babaliaros V, Cura F, Dager AE, Manoharan G, Lerakis S, Pichard AD, Radhakrishnan S, Perin MA, Dumont E, Larose E, Pasian SG, Nombela-Franco L, Urena M, Tuzcu EM, Leon MB, Amat-Santos IJ, Leipsic J, Rodés-Cabau J. Predictive factors, management, and clinical outcomes of coronary obstruction following transcatheter aortic valve implantation: insights from a large multicenter registry. J Am Coll Cardiol. 2013;62(17):1552–1562. doi: 10.1016/j.jacc.2013.07.040.
- Trenkwalder T, Lahmann AL, Nowicka M, Pellegrini C, Rheude T, Mayr NP, Voss S, Bleiziffer S, Lange R, Joner M, Kasel AM, Kastrati A, Schunkert H, Husser O, Hadamitzky M, Hengstenberg C. Incidental findings in multislice computed tomography prior to transcatheter aortic valve implantation: frequency, clinical relevance and outcome. Int J Cardiovasc Imaging. 2018;34(6):985–992. doi: 10.1007/s10554-018-1305-5.
- Hayashida K, Bouvier E, Lefèvre T, Hovasse T, Morice MC, Chevalier B, Romano M, Garot P, Mylotte D, Farge A, Donzeau-Gouge P, Cormier B. Impact of CT-guided valve sizing on post-procedural aortic regurgitation in transcatheter aortic valve implantation. EuroIntervention. 2012;8(5):546–555. doi: 10.4244/EIJV8I5A85.
- Khalique OK, Hahn RT, Gada H, Nazif TM, Vahl TP, George I, Kalesan B, Forster M, Williams MB, Leon MB, Einstein AJ, Pulerwitz TC, Pearson GD, Kodali SK. Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2014;7(8): 885–894. doi: 10.1016/j.jcin.2014.03.007.
- Suchá D, Tuncay V, Prakken NH, Leiner T, van Ooijen PM, Oudkerk M, Budde RP. Does the aortic annulus undergo conformational change throughout the cardiac cycle? A systematic review. Eur Heart J Cardiovasc Imaging. 2015;16(12):1307–1317. doi: 10.1093/ehjci/jev210.
- Zamorano JL, Gonçalves A, Lang R. Imaging to select and guide transcatheter aortic valve implantation. Eur Heart J. 2014;35(24):1578– 1587. doi: 10.1093/eurheartj/eht569.
- Fujita B, Kütting M, Seiffert M, Scholtz S, Egron S, Prashovikj E, Börgermann J, Schäfer T, Scholtz W, Preuss R, Gummert J, Steinseifer U, Ensminger SM. Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging. 2016;17(12):1385– 1393. doi: 10.1093/ehjci/jev343.
- Perlman GY, Blanke P, Webb JG. Transcatheter aortic valve implantation in bicuspid aortic valve stenosis. EuroIntervention. 2016;12(Y):Y42–Y45. doi: 10.4244/EIJV12SYA10.
- Ribeiro HB, Nombela-Franco L, Urena M, Mok M, Pasian S, Doyle D, DeLarochellière R, Côté M, Laflamme L, DeLarochellière H, Allende R, Dumont E, Rodés-Cabau J. Coronary obstruction following transcatheter aortic valve implantation: a systematic review. JACC Cardiovasc Interv. 2013;6(5):452–461. doi: 10.1016/j.jcin.2012.11.014.
- Maeno Y, Abramowitz Y, Kawamori H, Kazuno Y, Kubo S, Takahashi N, Mangat G, Okuyama K, Kashif M, Chakravarty T, Nakamura M, Cheng W, Friedman J, Berman D, Makkar RR, Jilaihawi H. A Highly Predictive Risk Model for Pacemaker Implantation After TAVR. JACC Cardiovasc Imaging. 2017;10(10 Pt A):1139–1147. doi: 10.1016/j.jcmg.2016.11.020.
- Murphy DT, Blanke P, Alaamri S, Naoum C, Rubinshtein R, Pache G, Precious B, Berger A, Raju R, Dvir D, Wood DA, Webb J, Leipsic JA. Dynamism of the aortic annulus: Effect of diastolic versus systolic CT annular measurements on device selection in transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr. 2016;10(1):37–43. doi: 10.1016/j.jcct.2015.07.008.
- Blanke P, Russe M, Leipsic J, Reinöhl J, Ebersberger U, Suranyi P, Siepe M, Pache G, Langer M, Schoepf UJ. Conformational pulsatile changes of the aortic annulus: impact on prosthesis sizing by computed tomography for transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2012;5(9):984–994. doi: 10.1016/j.jcin.2012.05.014.
- Latsios G, Spyridopoulos TN, Toutouzas K, Synetos A, Trantalis G, Stathogiannis K, Penesopoulou V, Oikonomou G, Brountzos E, Tousoulis D. Multi-slice CT (MSCT) imaging in pretrans-catheter aortic valve implantation (TAVI) screening. How to perform and how to interpret. Hellenic J Cardiol. 2018;59(1):3–7. doi: 10.1016/j.hjc.2017.09.013.
- Barbanti M, Buccheri S, Rodés-Cabau J, Gulino S, Généreux P, Pilato G, Dvir D, Picci A, Costa G, Tamburino C, Leon MB, Webb JG. Transcatheter aortic valve replacement with new-generation devices: A systematic review and meta-analysis. Int J Cardiol. 2017;245:83– 89. doi: 10.1016/j.ijcard.2017.07.083.
- Имаев ТЭ, Комлев АЕ, Колегаев АС, Лепилин ПМ, Акчурин РС. Современное состояние проблемы транскатетерного репротезирования клапанов сердца по методике «клапан-в-клапан». Consilium Medicum. 2016;18(5):89–92.
- Коков ЛС, Соколов ВВ, Пархоменко МВ, Муслимов РШ, Буланова МВ, Бикбова НМ. Транскатетерная имплантация биопротеза аортального клапана на нитиноловом саморасширяющемся каркасе по методике «клапан в клапан» в связи с дегенерацией створок первичного биопротеза. Клиническое наблюдение пациентки с высоким хирургическим риском. Вестник трансплантологии и искусственных органов. 2020;22(3):107– 114. doi: 10.15825/1995-1191-2020-3-107-114.
- Fukui M, Bing R, Dweck M, Cavalcante JL. Assessment of Aortic Stenosis by Cardiac Magnetic Resonance Imaging: Quantification of Flow, Characterization of Myocardial Injury, Transcatheter Aortic Valve Replacement Planning, and More. Magn Reson Imaging Clin N Am. 2019;27(3):427–437. doi: 10.1016/j.mric.2019.04.004.
- de Vaan J, Verstraeten L, de Jaegere P, Schultz C. The 3mensio Valves™ multimodality workstation. EuroIntervention. 2012;7(12):1464–1469. doi: 10.4244/EIJV7I12A228.
- Watanabe Y, Morice MC, Bouvier E, Leong T, Hayashida K, Lefèvre T, Hovasse T, Romano M, Chevalier B, Donzeau-Gouge P, Farge A, Cormier B, Garot P. Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Interv. 2013;6(9):955–964. doi: 10.1016/j.jcin.2013.05.008.